liquid nitrous oxide vacuum cryogenic storage tank

classification:vacuum cryogenic storage tank

publishtime:2019-11-25 13:05:51

hotline: 86 512-81666096

contact

description

n2o low-temperature vacuum storage tank for nitrous oxide is a double-layer container composed of inner and outer containers. it is a vacuum powder insulation type, which can be divided into two types: horizontal type and discrete type. the inner container material is 06cr19ni10, the outer container material is 16mnr according to the user's region, and the inner and outer containers are filled with insulation material pearlite and vacuumized.

introduce

operating temperature: - 90 ° c

working pressure 2.16mpa (can be designed according to customer's demand)

effective volume: 5m3, 10m3, 15m3, 20m3, 30m3, 50m3, 100m3, 100m3, 150m3, 100m3, 150m3, 100m3, 150m3, 100m3, 100m3, 50m3, 100m3, 50m3, 100m3, 50m3, 100m3, 50m3, 100m3, 50m3, 100m3, 50m3. non standard models can be customized.


insulation method

the insulation material is pearlite in hot state, which is used to fill the interlayer and vacuum

effective volume: less than or equal to 10m 3, vacuum degree ≤ 2pa, more than 10m 3, less than or equal to 50m 3, vacuum degree ≤ 3pa, more than 50m 3, less than or equal to 100m 3, vacuum degree ≤ 5pa, with exquisite technology, unique filling process, quality assurance commitment, in order to achieve the best insulation effect.

nitrous oxide low temperature vacuum storage tank adopts "combined safety system valve", which uses two groups of safety valves to work at the same time. when the safety valve is checked regularly, one side can be closed, and the other side can continue to work, so as to ensure the safe operation of the storage tank.

a pressure gauge, a differential pressure liquid level gauge and a liquid level comparison gauge are set on the upper part of the inner tank, so that the storage capacity and pressure change of the inner tank can be mastered at any time, which is convenient for filling and discharging.

the lower part of the tank is equipped with special tank vacuum detection, vacuum regulation and vacuum valve, which can be used to detect the interlayer vacuum regularly or at any time, so as to ensure the safe operation of the tank.