hotline
86 512-81666096-
185、characteristics of carbon dioxide spherical tank - doer equipment
characteristics of carbon dioxide spherical tank carbon dioxide spherical tank is a spherical tank with uniform stress on the shell. under the same diameter and working conditions,…
[2021.12.18] -
184. fire (detection) alarm system for large liquid ammonia cryogenic liquid full capacity …
fire (detection) alarm system for large liquid ammonia cryogenic liquid full capacity tankfor fire (detection) alarm system of large liquid ammonia cryogenic liquid full capacity t…
[2021.09.04] -
183、large liquid ammonia cryogenic liquid full capacity tank fire protection system - doer…
large liquid ammonia cryogenic liquid full capacity tank fire protection system spray cooling device for fire fighting system of large liquid ammonia low temperature liquid full cap…
[2021.08.28] -
182、temperature measurement of large liquid ammonia cryogenic liquid full volume tank - do…
temperature measurement of large liquid ammonia cryogenic liquid full volume tank temperature measurement of large liquid ammonia cryogenic liquid full volume tank. temperature meas…
[2021.08.14] -
181、 liquid level measurement and control measures of large liquid ammonia cryogenic liqui…
liquid level measurement and control measures of large liquid ammonia cryogenic liquid full volume tankliquid level measurement and control measures for large liquid ammonia cryogen…
[2021.07.31] -
180、pressure measurement and control measures of large liquid ammonia cryogenic liquid ful…
pressure measurement and control measures of large liquid ammonia cryogenic liquid full capacity tankthe pressure measurement and control measures of large liquid ammonia low temper…
[2021.07.24] -
179、process flow of large liquid ammonia low temperature full capacity tank system (part 2…
process flow of large liquid ammonia low temperature full capacity tank system (part 2) discharge of large liquid ammonia low-temperature full volume tank and outlet of storage tank…
[2021.07.17] -
178、process flow of large liquid ammonia low temperature full volume tank system (i) - doe…
process flow of large liquid ammonia low temperature full volume tank system (i)process overview of large liquid ammonia low-temperature full volume tank system is that the liquid a…
[2021.07.10] -
177、 selection of main equipment and materials for large liquid ammonia cryogenic liq…
selection of main equipment and materials for large liquid ammonia cryogenic liquid full capacity tankthe large liquid ammonia cryogenic liquid full capacity tank adopts double-laye…
[2021.07.03] -
176、technical parameters of large liquid ammonia low temperature full capacity tank - doer…
technical parameters of large liquid ammonia low temperature full capacity tanklarge liquid ammonia low-temperature full capacity tank is stored in the inner tank (main container) o…
[2021.06.26] -
175、structure and characteristics of large liquid ammonia cryogenic full capacity tank - d…
the large-scale liquid ammonia low-temperature full tank adopts the flat bottom cylinder bimetal full tank structure. the main design standard of the full tank is api620-2018 "…
[2021.06.19] -
174、description of fire fighting and telecommunication system of large ethylene cryogenic …
description of fire fighting and telecommunication system for large ethylene cryogenic full tankdescription of fire fighting and telecommunication system for large ethylene cryogeni…
[2021.06.05] -
173、instrument control description of large ethylene cryogenic full capacity tank - doer e…
instrument control description of large ethylene cryogenic full capacity tank1. pressure measurement and control measures of large ethylene cryogenic full capacity tankdoer to heat…
[2021.05.29] -
172、process flow of large ethylene cryogenic full capacity tank system - doer equipment
process flow of large ethylene cryogenic full capacity tank systemprocess overview of large ethylene cryogenic full capacity tank systemthe liquid ethylene sent from the ethylene un…
[2021.05.22] -
171、technical parameters of large ethylene cryogenic full capacity tank - doer equipment
technical parameters of large ethylene low temperature full capacity tankthe technical parameters of large ethylene low temperature full capacity tank are as follows:
[2021.05.15] -
170、structure and characteristics of large ethylene cryogenic full capacity tank - doer eq…
structure and characteristics of large ethylene cryogenic full capacity tankethylene liquid is stored in the inner tank (main container) of the full capacity tank, and the outer tan…
[2021.05.08] -
169、knowledge explanation of nitrous oxide storage tank -doer equipment
knowledge explanation of nitrous oxide storage tank - doer equipmentwhat is nitrous oxide? let's all understand the following knowledge about nitrogen oxidation!
[2021.01.23] -
168、on tank test method - doer equipment
about tank test methodsbutt weld inspection of storage tank: first conduct 100% nondestructive testing (rt), then penetrant inspection and air pressure (pure nitrogen) test, and fin…
[2021.01.08] -
167、product performance description of cryogenic liquid storage tank - doer equipment
product performance description of cryogenic liquid storage tankthe cryogenic liquid storage tank adopts two liquid inlet modes at the top and bottom, which can be selected and used…
[2020.12.31] -
166、description of product structure of cryogenic liquid storage tank - doer equipment
description of product structure of cryogenic liquid storage tankthe cryogenic liquid storage tank is of vertical double cylinder structure. the inner cylinder is made of s30408 sta…
[2020.12.26]