hotline
86 512-81666096-
125,lng sub master tank - doer equipment
lng sub tanklng sub master tank refers to the tank in which multiple sub tanks containing lng are connected in parallel and placed in the master tank filled with thermal insulation …
[2019.11.28] -
图124,20000m ³ calculation sheet for fire sprinkler water of lng full capacity tank - doer…
20000m ³ calculation sheet for fire sprinkler water of lng full capacity tank1. 20000m ³ standard specifications and basis adopted in the design of fire sprinkler water calculation …
[2019.11.20] -
123,20000m ³ dry powder calculation of lng full capacity tank (part 2) - doer equipment
20000m ³ dry powder calculation of lng full capacity tank (part 2)20000m ³ dry powder calculation of lng full capacity tank (part 2)
[2019.11.20] -
122,20000m ³ dry powder calculation sheet of lng full capacity tank (part i) - doer equipm…
20000m ³ dry powder calculation sheet of lng full capacity tank (part i)1)20000m ³ code for design of dry powder fire extinguishing of lng full capacity tank (gb50347-2004)
[2019.11.19] -
121,20000m ³ calculation of maximum make-up gas volume of lng full capacity tank - doer eq…
20000m ³ calculation of maximum make-up gas volume of lng full capacity tanktwenty thousand ³ determination of gas make-up volume of lng full capacity tank
[2019.11.19] -
120,20000m ³ bog calculation under leakage condition of lng full capacity tank - doer equi…
20000m ³ bog calculation under leakage condition of lng full capacity tank20000m ³ according to gb / t 26978.1-2011 design and construction of on-site assembled vertical cylindrical…
[2019.11.18] -
119,calculation of maximum discharge capacity (bog) under tank fire and rollover condition…
calculation of maximum discharge capacity (bog) under tank fire and tumbling conditions (part 2)as for the calculation of maximum discharge capacity (bog) under tank fire and tumbli…
[2019.11.18] -
118,calculation of maximum discharge capacity (bog) under tank fire and rollover condition…
calculation of maximum discharge capacity (bog) under tank fire and tumbling conditionsdetermination of discharge capacity
[2019.11.16] -
117,calculation of maximum gasification capacity (bog) under storage tank operating condit…
calculation of maximum gasification capacity (bog) under storage tank operating conditionsthe maximum gasification capacity of the storage tank under operating conditions shall cons…
[2019.11.16] -
116,pressurization system of lng vacuum powder storage tank (without pressurization of sto…
pressurization system of lng vacuum powder storage tank (no pressurization of storage tank) (iii)function: when the pressure of the storage tank is too low, open the pressurization …
[2019.11.14] -
115,problems and solutions of pressure gauge of lng vacuum powder storage tank (ii) - doer…
problems and solutions of pressure gauge of lng vacuum powder storage tank (ii)function: displays the current pressure of the storage tank.
[2019.11.14] -
114,common problems and solutions of lng vacuum powder storage tank (i) - doer equipment
common problems and solutions of lng vacuum powder storage tank (i)1. problems and solutions of safety valve
[2019.11.13] -
113,air pressure, air tightness test and vacuum test of outer tank before tank constructio…
air pressure, air tightness test and vacuum test of outer tank before tank construction (part ii)6) external tank vacuum test of storage tank
[2019.11.13] -
图112,air pressure, air tightness test and vacuum test of outer tank before tank construct…
air pressure, air tightness test and vacuum test of outer tank before tank construction1) conditions to be met before outer tank air tightness test of storage tank:
[2019.11.12] -
图111,tank hydrostatic test before tank construction (3) - doer equipment
tank hydrostatic test before tank constructionhydrostatic test of inner tank before tank construction
[2019.11.12] -
图110,preparation of water and gas sources before tank construction (2) - doer equipment
preparation of water and gas sources before tank construction:(a) the water source is supplied directly from pvc. the water supply pressure (capping pressure) shall reach 0.5mpa and…
[2019.11.11] -
109,preparation before tank construction (1) - doer equipment
preparation before tank construction (1)procedures to be completed before water filling of the tank: apply a liquid film to all welds on the tank bottom and the fully welded and ful…
[2019.11.11] -
图108,tank water pressure test - doer equipment
water pressure test of storage tank1 test purpose
[2019.11.09] -
图107,do you know the main structure of the tank- doer equipment
do you know the main structure of the tank?inner tank (main container)
[2019.11.08] -
图106,analysis of liquid level measurement and control measures of lng storage tank (2) - …
analysis of liquid level measurement and control measures of lng storage tankthe storage tank is equipped with two servo liquid level meters and one radar liquid level meter to cont…
[2019.11.02]